Skip to main content
Fontana Logo
File #: 25-0448    Version: 1 Name:
Type: Public Hearing Status: Agenda Ready
File created: 8/11/2025 In control: Planning Commission
On agenda: 8/19/2025 Final action:
Title: Master Case No. 23-0101: Conditional Use Permit No. 24-0022, and Design Review No. 23-0024; A request for the development of a mixed use project (163 multi-family units and 5,000 square feet of commercial retail) within the R-5 zoning district and for site and architectural review of a five-story 83,125 square foot mixed-use building and associate improvements, on a 3.5 acre site located on the northeast corner of Foothill Boulevard and Sultana Avenue (APNs: 1110-331-13 and 1110-331-25), pursuant to a Categorical Exemption in accordance with CEQA Guidelines Section 15332.
Attachments: 1. Attachment No. 1 - Vicinity Map, 2. Attachment No. 2 - Project Plans, 3. Attachment No. 3 - PC Resolution, 4. Attachment No. 4 - Notice of Exemption, 5. Attachment No. 5 - Public Hearing

FROM:

Planning Department

 

TITLE:

Title

Master Case No. 23-0101: Conditional Use Permit No. 24-0022, and Design Review No. 23-0024; A request for the development of a mixed use project (163 multi-family units and 5,000 square feet of commercial retail) within the R-5 zoning district and for site and architectural review of a five-story 83,125 square foot mixed-use building and associate improvements, on a 3.5 acre site located on the northeast corner of Foothill Boulevard and Sultana Avenue (APNs: 1110-331-13 and 1110-331-25), pursuant to a Categorical Exemption in accordance with CEQA Guidelines Section 15332.

End

 

RECOMMENDATION:

Based on the information in the staff report and resolution, and subject to the attached Findings and Conditions of Approval, staff recommends that the Planning Commission adopt Resolution PC No. 2025-____, and

 

1. Determine that the project is categorically exempt pursuant to Section No. 15332 (Class No. 32. Infill Development) of the California Environmental Quality Act (CEQA), and Section No. 3.22 (Categorical Exemption) of the Local 2019 Guidelines for Implementing the CEQA, and direct staff to file a Notice of Exemption; and

 

2. Approve Conditional Use Permit (CUP) No. 24-0022; and

 

3. Approve Design Review (DRP) No. 23-0024.

 

APPLICANT:

Andresen Architecture, Inc.

17087 Orange Way

Fontana, CA 92335

 

LOCATION:

The project site is located on the northeast corner of Foothill Boulevard and Sultana Avenue (APNs: 1110-331-13 and 1110-331-25).

 

REQUEST:

Conditional Use Permit (CUP) No. 24-0022- A request for the establishment of mixed-used project within an R-5 zone.

 

Design Review (DR) No. 23-0024 - A request for site and architectural approval for a new five (5) story, mixed-use development building consisting of 163 multifamily units, with amenities, retail use, and a first-floor parking garage.

 

PROJECT PLANNER:

Salvador Quintanilla, Senior Planner

 

 

BACKGROUND INFORMATION:

Land Use Table:

 

 

General Plan

Zoning/Overlay

Existing Land Use

Site:

Multi-Family High Density  (R-MFH)

Multi-Family High Density Residential (R-5)

Vacant

North:

Public Facility (P-PF)

Public Facility (P-PF)

Pacific Electric Trail

South:

General Commercial  (C-G)/County of San Bernardino

General Commercial (C-2)/ County of San Bernardino

Warehouse Building

East:

General Commercial (C-G)

General Commercial  (C-2)

Vacant

West:

Multi-Family Residential/Multi-Family High Density  (R-MF/ R-MFH)

Multiple Family/ Multi Family High Density Residential (R-3/R-5)

Water tank and supporting building/Vacant

 

 

PROJECT DESCRIPTION:

 

A.                     Site Area:                                                               151,589 square feet, approximately 3.5 acres

B.                     Building Analysis:

Height                                                               62’9” at corner roof top deck

 

Retail                                                               5,000 square feet

Multifamily Units      163

ADU Units                                          41

C.                     Parking:

Vehicle Required:                                          274 parking spaces

Vehicle Provided:                                          277 parking spaces

D.                     Landscaping:

Required:                                                               10,270 square feet (15 percent)

Provided”                                                               22,383 square feet (32.6 percent)

 

 

ANALYSIS:

The applicant, Andresen Architecture, Inc., is requesting that the Planning Commission review and approve Conditional Use Permit No. 24-0022 for the establishment of a mixed-use development within an R-5 zoning district and approve Design Review No. 23-0024 for site and architectural review for the development of a new five (5) story mixed-use project which includes 163 multi-family units and 5,000 square feet of commercial retail. The ADUs are depicted on the plans and in the summary for informational purposes only; they are not a part of the Planning Commission’s consideration as they are not subject to discretionary review. 

 

The project site is located on the northeast corner of Sultana Avenue and Foothill Boulevard. The project consists of a rectangular building with parking, commercial retail on the first floor and multi-family units on the 3rd through 5th floor, and amenities through various floors of the building.

 

Currently, the site is vacant and comprised of two (2) parcels totaling 3.5 acres that will be consolidated into (1) parcel as part of a future lot line adjustment.

 

Conditional Use Permit No. 24-0022

The project is a vertical mixed-use project, that includes residential units above ground-floor commercial uses. Mixed use projects are permitted in the R-5 zoning district with the approval of a Conditional Use Permit (CUP).  As identified in the Zoning and Development Code and as proposed, this mixed-use project supports transit use by providing a denser residential project, enhances access to public transportation, and encourages pedestrian activities and use of non-motor vehicle transportation.  The project is located along Foothill Boulevard, a major bus corridor in Fontana that provides access to the Fontana Metrolink station.  In addition, the project promotes pedestrian activities by establishing a pedestrian commercial use along Foothill Boulevard.  The building is pulled back at the corner of Foothill Boulevard and Sultana Avenue to create a more comfortable pedestrian space at the intersection.

 

Design Review (DRP) No. 23-0024

The proposed five-story mixed-use building will be comprised of 163 multi-family units with amenities. Five (5) 1,000 square foot retail units are proposed on the ground floor along with a 277-vehicle parking spaces. The 1,054 square foot units, 1,000 square foot units and 863 square foot residential units are located on the second through fifth floors.

 

PLAN NO.

Type A

Type A

SIZE

1,054 sq. ft

1,000 sq. ft.

NO. BEDRMS

3-Bed

3-Bed

NO. BATHS

2-Bath

1-Bath

OPEN SPACE

107 sq. ft.

94-98 sq. ft.

 

The applicant proposes a Contemporary style of architecture for the building. The architectural features for the proposed building will incorporate a white/gray neutral tone color palette with black and blue accent, with aluminum panels and railings, stone and brick veneer, exterior metal doors, and glazed windows The variations to the building face, varying roof lines and building’s height from 55 feet high to 62.9 feet high at the front corner of the building, will make the project architecturally pleasing and be consistent with the surrounding area.  The project will contain amenities for the residents of all age groups; amenities include a BBQ island and seating area, corn hole, pool & spa, a fitness center, a recreation room with balcony, firepit and sitting area, as well as an amenity outdoor roof top deck with seating area for residential units’ use.

 

The Project includes associated on and off-site improvements to include installing parking spaces, impervious pedestrian paving, new landscaping, enhanced paving, and lighting.

 

Grading/Walls:

The topography of the Project Site is relatively flat. The existing drainage pattern flows from north to south, with the proposed drainage pattern to direct the water to the east into an underground storage chamber which will be installed as part of the project. The Project will construct a six (6) foot high masonry wall along the north side of the property along the Pacific Electric Trail, and a six (6) foot high wrought iron fence on the east and west side, with the west side having a decorative pilaster every 20-30 feet. Additionally, the main entrance to the multi-family area there will be a six (6) foot high wrought iron fence with a swing gate and a four-foot-wide man gate.

 

Site Access/Circulation/Parking:

The project includes vehicle ingress/egress on Sultana Avenue for residents only and on Foothill Boulevard for the retail patrons and the future residential tenants. Parking for the retail patrons will be located in the rear of the retail units that are facing Foothill Boulevard. Residential parking will be on the ground floor, with additional parking along the west and north property lines. The project size is suitable in size and shape to support the development of the proposed multi-family and retail use building.

 

The project site meets the minimum parking requirements pursuant to the Zoning and Development code based for this type of development. The internal circulation has been reviewed by Planning, Fire, Traffic, and Engineering. The internal circulation is sufficient to support this type of use.

 

The project site is physically suitable in size and shape to support the development of the proposed mixed-use development. Applicable building codes, zoning codes, and fire codes and standards will make for a safe, attractive, and well-designed project. The project design incorporates safety measures f/or pedestrians.

 

Environmental:

Pursuant to the California Environmental Quality Act (CEQA) Guidelines and Section No. 3.22 (Categorical Exemption) of the City of Fontana’s 2019 Local Guidelines for Implementing CEQA, the proposed Project is categorically exempt from CEQA pursuant to CEQA Guidelines Section No. 15332 as a Class 32, In-Fill Development Project. The project site is considered Infill Development and meets the CEQA requirements of Infill: (1) The Project is consistent with the Multi-family High Residential (R-MFH) designation of the General Plan and the Multi-family High Density Residential (R-5) zoning district; (2) The Project Site is less than five (5) acres at 3.5 acres; (3) The Project Site is not within any known sensitive or threatened habitat area; (4) The Project will not have any significant effects related to traffic, noise, air quality, or water quality; and (5) There are adequate public services for the development of the proposed residential project. Further, none of the exceptions in CEQA Guidelines section 15300.2 apply to the project.

 

MOTION:

Approve staff’s recommendation.

 

ATTACHMENTS:

Attachment No. 1 - Vicinity Map

Attachment No. 2 - Project Plans

Attachment No. 3 - Planning Commission Resolution, and Conditions of Approval

Attachment No. 4 - Notice of Exemption

Attachment No. 5 - Public Hearing Notice